Search published articles



J. Beiza, S. H. Hosseinian, B. Vahidi,
Volume 5, Issue 3 (9-2009)
Abstract

This paper presents a novel approach for fault type estimation in power systems. The Fault type estimation is the first step to estimate instantaneous voltage, voltage sag magnitude and duration in a three-phase system at fault duration. The approach is based on time-domain state estimation where redundant measurements are available. The current based model allows a linear mapping between the measured variable and the states to be estimated. This paper shows a possible for fault instance detection, fault location identification and fault type estimation utilizing residual analysis and topology error processing. The idea is that the fault status does not change measurement matrix dimensions but changes some elements of the measurement matrix. The paper addresses how to rebuilt measurement matrix for each type of faults. The proposed algorithm is shown that the method has high effectiveness and high performance for forecasting fault type and for estimating instantaneous bus voltage. The performance of the novel approach is tested on IEEE 14-bus test system and the results are shown.
H. Yaghobi, K. Ansari, H. Rajabi Mashhadi,
Volume 7, Issue 4 (12-2011)
Abstract

A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging problem in the area of fault diagnosis of electrical machines. The purpose of this challenge is to be more efficient in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detect the occurrence of the fault, but also locate its position in the winding. Hence, this paper presents a novel method for diagnosis of different kinds of inter-turn winding faults in a salient-pole synchronous generator using the change in the magnetic flux linkage. It describes the influence of inter-turn winding faults on the magnetic flux linkage distribution of the generator. The main feature of the proposed method is its capability to identify the faulty coils under two types of inter-turn winding faults. Also, simple algorithm, low cost sensor and sensitivity are the other feature in the proposed technique. In this method, generator air gap flux linkage is measured via search coils sensor installed under the stator wedges. Theoretical approach based on Finite Element Method (FEM) together with experimental results derived from a 4-pole, 380U, 1500 rpm, 50 Hz, 50 KVA, 3-phase salient-pole synchronous generator confirm the validity of the proposed method.
M. Mollanezhad Heydar-Abadi , A. Akbari Foroud,
Volume 9, Issue 3 (9-2013)
Abstract

Fault classification in distance protection of transmission lines, with considering the wide variation in the fault operating conditions, has been very challenging task. This paper presents a probabilistic neural network (PNN) and new feature selection technique for fault classification in transmission lines. Initially, wavelet transform is used for feature extraction from half cycle of post-fault three phase currents at one end of line. In the proposed method three classifiers corresponding with three phases are used which fed by normalized particular features as wavelet energy ratio (WER) and ground index (GI). The PNNs are trained to provide faulted phase selection in different ten fault types. Finally, logic outputs of classifiers and GI identify the fault type. The feasibility of the proposed algorithm is tested on transmission line using PSCAD/EMTDC software. Variation of operating conditions in train cases is limited, but it is wide for test cases. Also, quantity of the test data sets is larger than the train data sets. The results indicate that the proposed technique is high speed, accurate and robust for a wide variation in operating conditions and noisy environments.
F. Tootoonchian, F. Zare,
Volume 14, Issue 3 (9-2018)
Abstract

Disk Type Variable Reluctance (DTVR) resolvers have distinguished performance under run out fault comparing to conventional sinusoidal rotor resolvers. However, their accuracy under inclined rotor fault along with different types of eccentricities includes static and dynamic eccentricities are questioned. Furthermore, due to thin copper wires that are used for signal and excitation coils of resolver there is high risk of short circuit fault in the coils. So, in this study the performance of the sinusoidal rotor DTVR resolver under the mentioned faults are studied. The quality of output voltages along with position error of the sensor is discussed. 3-D time stepping finite element method is used to show the effect of different faults. Finally, the prototype of the studied resolver is constructed and tested. The employed test bed is built in such a way that is able to apply controllable level of different mechanical faults. Good agreement is obtained between the finite element and the experimental results, validating the success of the presented analysis.